Skip to main content

Table 5 Radiation dose constraints in this study

From: Efficacy and safety of FDG-PET for determining target volume during intensity-modulated radiotherapy for head and neck cancer involving the oral level

 

Target

Permissible range

PTV

Dmean

 = 100% (prescribed dose)

 

Dmax

 < 110%

 < 113%

D98

 > 93%

 > 90%

CTV

D99

 > 100%

 > 98%

Spinal cord*

Dmax

 < 50 Gy

 < 54 Gy

D1cm3

 < 46 Gy

 < 50 Gy

Brainstem

Dmax

 < 54 Gy

 < 64 Gy

D1cm3

 < 60 Gy

 

Optic nerve

Dmax

 < 50 Gy

 < 54 Gy

Optic chiasm

Dmax

 < 50 Gy

 < 54 Gy

Eyeball

Dmax

 < 40 Gy

 < 45 Gy

Lens

Dmax

 < 6 Gy

 < 10 Gy

Parotid gland

Dmean

 < 26 Gy

 < 30 Gy

Oral cavity

Dmean

 < 30 Gy

 < 40 Gy

Mandible

D2cm3

 < 66 Gy

 < 72 Gy

Larynx

Dmean

 < 45 Gy

 < 50 Gy

Pharyngeal constrictor

Dmean

 < 54 Gy

 < 60 Gy

  1. *Planning risk volume
  2. Dmean mean dose; Dmax maximum dose; D98 dose received by 98% of the volume; D99 dose received by 99% of the volume; D2cm3 minimum dose delivered to the highest irradiated 2 cm3 volume; D1cm3 minimum dose delivered to the highest irradiated 1 cm3 volume; PTV planning target volume; CTV clinical target volume